78380
New
Disponible
Warning: Last items in stock!
Availability date: 06/12/2026
| Quantity | Total amount | Price 1 unit |
|---|---|---|
| 5 | €28.56 | Price €5.71 |
Central flex for Blackview Rock 1 premium quality
Central flex for Blackview Rock 1 in premium quality, designed to restore the internal communication between device modules and ensure correct electrical continuity between the connected areas of the motherboard, sub-board, sensors or auxiliary components according to the internal architecture of the device. This spare part is suitable when the device has intermittent faults, loss of connection between modules, problems after impacts, moisture, previous handling or breakage of the original flexible cable. Its installation allows functional stability to be restored without replacing other components that are in good condition. In rugged devices such as the Blackview Rock 1, it is especially important to respect the flex route, avoid forced bends and check seating before final closure.
Specifications
• Component: internal central flex
• Compatibility: Blackview Rock 1
• Function: internal connection between device modules
• Quality: premium
Premium quality offers good flexibility, stable contact and suitable fit at the internal connection points of the Blackview Rock 1. It is a part suitable for repair shops that need to restore the electrical continuity of the device after a fault located in the flex cable, without unnecessarily intervening in other modules. Before final assembly, it is recommended to check connectors, clean contacts, make sure there is no adhesive residue or dirt in the routing area and perform a cold test. It is also advisable to verify the functions related to the replaced flex, paying attention to possible intermittent faults, chassis pressure and correct placement of gaskets or internal protections. Available for immediate shipping from Spain.
Installation tips
Disconnect the battery before handling any internal flex.
Use ESD protection throughout the repair.
Remove the damaged flex without forcing connectors or anchor points.
Align the new flex following the original route of the device.
Avoid marked bends, twisting or excessive pressure on the cable.
Perform a cold test before final closure.
Check the sealing, gaskets and chassis pressure after assembly.
Technical table
| Brand | Compatible models | Component type | Function | Quality |
|---|---|---|---|---|
| Blackview | Rock 1 | Internal central flex | Internal connection between device modules | Premium |